Linter Filtros Special Filters are manufactured with a galvanized steel frame and are designed to filter fine suspended particles such as bacteria, viruses, soot, dust, and others. They are used in various applications, mainly where space is limited. Their characteristics include reduced energy consumption, pressure drop, and a longer product lifespan.
Models
V Filter and PB Filter
Filter Media
Filter papers made of microfiber glass or synthetic fiber in pleated form with narrow creases, shallow depth and with different degrees of filtration.
sealant
Two-component polyurethane
Filtration Classification
EN 1822 – F8 / H13
Main Applications
Technical Specifications
| Models | Lost of Initial Load (Shovel) |
Lost of Final Load (Shovel) |
Surface Active / Cell (M²) |
Nominal Flow (m³ / h) |
Element Filtering |
Dimension⁽¹⁾ (mm) |
Temperature⁽²⁾ (° C) |
Weight (kg) |
Class |
|---|---|---|---|---|---|---|---|---|---|
| V - BLUE | 95 | 450 | 2,8 | 170 | Synthetic fiber | 600 x 65 x 202 | 70 | 1,40 | F8 (EN 779) |
| V - GLASS | 155 | 450 | 2,8 | 200 | Fiberglass | 600 x 65 x 202 | 70 | 1,15 | H13 (EN 1822) |
| PB-400/F8 | 140 | 450 | 1,7 | 130 | Synthetic fiber | 86,5 x 202 x 400 | 70 | 0,95 | F8 (EN 779) |
| PB-600/F8 | 140 | 450 | 2,8 | 180 | Synthetic fiber | 86,5 x 202 x 600 | 70 | 1,4 | F8 (EN 779) |
| PB-400/H13 | 200 | 450 | 1,7 | 150 | Fiberglass | 86,5 x 202 x 400 | 70 | 0,8 | H13 (EN 1822) |
| PB-600/H13 | 200 | 450 | 2,8 | 200 | Fiberglass | 86,5 x 202 x 600 | 70 | 1,2 | H13 (EN 1822) |
⁽¹⁾ W x H x D: Width x Height x Depth.
⁽²⁾ Above 70 °C, consult our technical department.
Technical Specifications
| Models | Lost of Initial Load (Shovel) |
Lost of Final Load (Shovel) |
Surface Active / Cell (M²) |
Nominal Flow (m³ / h) |
Element Filtering |
Dimension⁽¹⁾ (mm) |
Temperature⁽²⁾ (° C) |
Weight (kg) |
Class |
|---|---|---|---|---|---|---|---|---|---|
| V - BLUE | 95 | 450 | 2,8 | 170 | Synthetic fiber | 600 x 65 x 202 | 70 | 1,40 | F8 (EN 779) |
| V - GLASS | 155 | 450 | 2,8 | 200 | Fiberglass | 600 x 65 x 202 | 70 | 1,15 | H13 (EN 1822) |
| PB-400/F8 | 140 | 450 | 1,7 | 130 | Synthetic fiber | 86,5 x 202 x 400 | 70 | 0,95 | F8 (EN 779) |
| PB-600/F8 | 140 | 450 | 2,8 | 180 | Synthetic fiber | 86,5 x 202 x 600 | 70 | 1,4 | F8 (EN 779) |
| PB-400/H13 | 200 | 450 | 1,7 | 150 | Fiberglass | 86,5 x 202 x 400 | 70 | 0,8 | H13 (EN 1822) |
| PB-600/H13 | 200 | 450 | 2,8 | 200 | Fiberglass | 86,5 x 202 x 600 | 70 | 1,2 | H13 (EN 1822) |
⁽¹⁾ W x H x D: Width x Height x Depth.
⁽²⁾ Above 70 °C, consult our technical department.
Technical Drawing V Filter

Technical Drawing PB Filter

Select the desired option
Technical Drawing V Filter

Technical Drawing PB Filter

Documentation
Complete Line of Filters and Equipment
29 Years of Experience
Prompt Delivery Filters
The Best Commercial Conditions

You can also contact us by email at contato@linterfiltros.com.br