Table of Air Filters Linter Filters - Filtration Classes
Click on the image for information about the filters.
Filtration Classification Coarse, Medium, Fine and Absolute HEPA Filters
Class NBR ISO 16890 | |||||
Group of filters |
Class NBR16101 |
ISO Coarse (Efficiency @ PM 10 < 50%) |
ISO ePM 10 | ISO ePM2,5 | ISO ePM1 |
thick | G1 | ||||
G2 | |||||
G3 | > 60% | ||||
G4 | > 70% | ||||
Medium | M5 | Ef > 50% | 10% ≤ Ef < 50% | 5% ≤ Ef < 40% | |
M6 | Ef > 60% | 50% ≤ Ef < 65% | 10% ≤ Ef < 45% | ||
fines | F7 | Ef > 85% | 65% ≤ Ef < 80% | 50% ≤ Ef < 65% | |
F8 | Ef > 90% | Ef > 80% | 65% ≤ Ef < 80% | ||
F9 | Ef > 95% | Ef > 95% | Ef > 80% |
NBR ISO29463 | Overall Value | Local Value (a, b) | EN 1822 | ||
Filter Class and Group | Efficiency (%) to MPPS |
Penetration (%) to MPPS |
Efficiency (%) to MPPS |
Penetration (%) to MPPS |
Class and Group of the Filter |
85 ≥ | ≤ 15 | N/A c | N/A c | E10 | |
ISO 15E | 95 ≥ | ≤ 5 | N/A c | N/A c | E11 |
ISO 20E | 99 ≥ | ≤ 1 | N/A c | N/A c | E12 |
ISO 25E | 99,5 ≥ | ≤ 0,5 | N/A c | N/A c | E12 |
ISO 30E | 99,9 ≥ | ≤ 0,1 | N/A c | N/A c | E12 |
ISO 35H (D) | 99,95 ≥ | ≤ 0,05 | 99,75 ≥ | ≤ 0,25 | H13 |
ISO 40H (D) | 99,99 ≥ | ≤ 0,01 | 99,75 ≥ | ≤ 0,05 | H14 |
ISO 45H (D) | 99,995 ≥ | ≤ 0,005 | 99,975 ≥ | ≤ 0,025 | H14 |
ISO 50U | 99,999 ≥ | ≤ 0,001 | 99,995 ≥ | ≤ 0,005 | H14 |
ISO 55U | 99,9995 ≥ | ≤ 0,0005 | 99,9975 ≥ | ≤ 0,0025 | H14 |
ISO 60U | 99,9999 ≥ | ≤ 0,0001 | 99,9995 ≥ | ≤ 0,0005 | U15 |
ISO 65U | 99,99995 ≥ | ≤ 0,00005 | 99,99975 ≥ | ≤ 0,00025 | U16 |
ISO 70U | 99,99999 ≥ | ≤ 0,00001 | 99,9999 ≥ | ≤ 0,0001 | U16 |
ISO 75U | 99,999995 ≥ | ≤ 0,00005 | 99,9999 ≥ | ≤ 0,0001 | U17 |
(a) See item 7.5.2 of NBR ISO 29463-1 and ISO29463-4
(b) Penetration values lower than those contained in this Table may be agreed between customers and supplier
(c) Group E filters cannot and must not be leak tested for classification purposes.
(d) For group H filters, the local penetration is given by the particle scanning method for the MPPS. Alternative limits may be specified when the photometer and oil mist leak test are used.
Conversion table
CONVERSION TABLE - ENGLISH SYSTEM / METRIC SYSTEM | ||
---|---|---|
English → Metric | Metric → English | |
Length | 1 in = 25,4 mm | 1 mm = 0.03937 in |
1in=2,54cm | 1cm=0.3937in | |
1 in = 0,0254 m | 1 m = 39.37 in | |
1ft = 304,8 mm | 1 mm = 0.00328 ft | |
1ft = 30,48 cm | 1 cm = 0.328 feet | |
1ft = 0,3048 m | 1m = 3.2808ft | |
Area | 1 in² = 6,4516 cm² | 1 cm² = 1.55 in² |
1 ft² = 0,0929 m² | 1 m² = 10.764 ft² | |
Volume | 1 in³ = 16387 cm³ | 1 cm³ = 0.061 in³ |
1 ft³ = 0,0283 m³ | 1 m³ = 35.315 ft³ | |
Speed | 1 fpm = 0,00508 m/s | 1 m/s = 196.85 fpm |
Air flow | 1 cfm = 0,0047 m³/s | 1 m³/s = 2118.9 cfm |
1 cfm = 0,0283 m³/min | 1 m³/min = 35.315 cfm | |
1 cfm = 1699 m³/h | 1 m³/h = 0.5886 cfm | |
Cargo loss | 1 in. WG = 248,8 Pa | 1 Pa = 0.00402 in. WG |
Shot put | 1 lb = 454 g | 1kg = 2.203 lbs |
1 lb = 0,454 kg | ||
Temperature | °F = 1,8 °C +32 | °C = .5556 °F -18 |
Table of Air Filters Linter Filters - Filtration Classes
Click on the image for information about the filters.
Filtration Classification Coarse, Medium, Fine and Absolute HEPA Filters
Class NBR ISO 16890 | |||||
Group of filters |
Class NBR16101 |
ISO Coarse (Efficiency @ PM 10 < 50%) |
ISO ePM 10 | ISO ePM2,5 | ISO ePM1 |
thick | G1 | ||||
G2 | |||||
G3 | > 60% | ||||
G4 | > 70% | ||||
Medium | M5 | Ef > 50% | 10% ≤ Ef < 50% | 5% ≤ Ef < 40% | |
M6 | Ef > 60% | 50% ≤ Ef < 65% | 10% ≤ Ef < 45% | ||
fines | F7 | Ef > 85% | 65% ≤ Ef < 80% | 50% ≤ Ef < 65% | |
F8 | Ef > 90% | Ef > 80% | 65% ≤ Ef < 80% | ||
F9 | Ef > 95% | Ef > 95% | Ef > 80% |
NBR ISO29463 | Overall Value | Local Value (a, b) | EN 1822 | ||
Filter Class and Group | Efficiency (%) to MPPS |
Penetration (%) to MPPS |
Efficiency (%) to MPPS |
Penetration (%) to MPPS |
Class and Group of the Filter |
85 ≥ | ≤ 15 | N/A c | N/A c | E10 | |
ISO 15E | 95 ≥ | ≤ 5 | N/A c | N/A c | E11 |
ISO 20E | 99 ≥ | ≤ 1 | N/A c | N/A c | E12 |
ISO 25E | 99,5 ≥ | ≤ 0,5 | N/A c | N/A c | E12 |
ISO 30E | 99,9 ≥ | ≤ 0,1 | N/A c | N/A c | E12 |
ISO 35H (D) | 99,95 ≥ | ≤ 0,05 | 99,75 ≥ | ≤ 0,25 | H13 |
ISO 40H (D) | 99,99 ≥ | ≤ 0,01 | 99,75 ≥ | ≤ 0,05 | H14 |
ISO 45H (D) | 99,995 ≥ | ≤ 0,005 | 99,975 ≥ | ≤ 0,025 | H14 |
ISO 50U | 99,999 ≥ | ≤ 0,001 | 99,995 ≥ | ≤ 0,005 | H14 |
ISO 55U | 99,9995 ≥ | ≤ 0,0005 | 99,9975 ≥ | ≤ 0,0025 | H14 |
ISO 60U | 99,9999 ≥ | ≤ 0,0001 | 99,9995 ≥ | ≤ 0,0005 | U15 |
ISO 65U | 99,99995 ≥ | ≤ 0,00005 | 99,99975 ≥ | ≤ 0,00025 | U16 |
ISO 70U | 99,99999 ≥ | ≤ 0,00001 | 99,9999 ≥ | ≤ 0,0001 | U16 |
ISO 75U | 99,999995 ≥ | ≤ 0,00005 | 99,9999 ≥ | ≤ 0,0001 | U17 |
(a) See item 7.5.2 of NBR ISO 29463-1 and ISO29463-4
(b) Penetration values lower than those contained in this Table may be agreed between customers and supplier
(c) Group E filters cannot and must not be leak tested for classification purposes.
(d) For group H filters, the local penetration is given by the particle scanning method for the MPPS. Alternative limits may be specified when the photometer and oil mist leak test are used.
Conversion table
English → Metric | Metric → English | |
---|---|---|
Length | 1 in = 25,4 mm | 1 mm = 0.03937 in |
Length | 1in=2,54cm | 1cm=0.3937in |
Length | 1 in = 0,0254 m | 1 m = 39.37 in |
Length | 1ft = 304,8 mm | 1 mm = 0.00328 ft |
Length | 1ft = 30,48 cm | 1 cm = 0.328 feet |
Length | 1ft = 0,3048 m | 1m = 3.2808ft |
Area | 1 in² = 6,4516 cm² | 1 cm² = 1.55 in² |
Area | 1 ft² = 0,0929 m² | 1 m² = 10.764 ft² |
Volume | 1 in³ = 16387 cm³ | 1 cm³ = 0.061 in³ |
Volume | 1 ft³ = 0,0283 m³ | 1 m³ = 35.315 ft³ |
Speed | 1 fpm = 0,00508 m/s | 1 m/s = 196.85 fpm |
Air flow | 1 cfm = 0,0047 m³/s | 1 m³/s = 2118.9 cfm |
Air flow | 1 cfm = 0,0283 m³/min | 1 m³/min = 35.315 cfm |
Air flow | 1 cfm = 1699 m³/h | 1 m³/h = 0.5886 cfm |
Cargo loss | 1 in. WG = 248,8 Pa | 1 Pa = 0.00402 in. WG |
Shot put | 1 lb = 454 g | 1kg = 2.203 lbs |
Shot put | 1 lb = 0,454 kg | 1kg = 2.203 lbs |
Temperature | °F = 1,8 °C +32 | °C = .5556 °F -18 |
Complete Line of Filters and Equipment
29 Years of Experience
Prompt Delivery Filters
The Best Commercial Conditions
You can also contact us by email contato@linterfiltros.com.br